  • 6(2).jpg

Halogen-free environmental protection non-flame retardant medical heat shrink tube


Product Overview:

KY-MT-90R-NV-X Non-flame retardant medical heat shrink tubing is a cross-linked low-density polyethylene (LDPE) heat shrink tubing with excellent flexibility and the best choice for strain relief applications good choice. Its uniform structure contributes to its consistency and high performance, making this product virtually free from defects, pinholes, seams, cracks or specks. Has a high shrinkage ratio (4:1, 5;1) and is the best choice for strain relief applications.
Contact us
  • Product Features
  • Specifications
  • Technical data
  • Video
  • KY-MT-90R-NV-X Non-flame retardant medical heat shrink tubing is a cross-linked low-density polyethylene (LDPE) heat shrink tubing with excellent flexibility and the best choice for strain relief applications good choice. Its uniform structure contributes to its consistency and high performance, making this product virtually free from defects, pinholes, seams, cracks or specks. Has a high shrinkage ratio (4:1, 5;1) and is the best choice for strain relief applications.

     

    Compliant with human contact Insulation properties Strong wear resistance Strong environmental protection High shrinkage

     

    Features

    ◎Shrink ratio: 2:1

    ◎Operating temperature: -45°C to +90°C

    ◎Initial shrinkage temperature: ≥+80℃

    ◎Excellent electrical insulation performance

    ◎Abrasion resistance

    ◎Conforms to ISO 10993-1

    ◎Environmental protection standard: RoHS compliant

    ◎Standard color: transparent, black (other colors can be customized)

    Key words:
    • Halogen-free environmental protection non-flame retardant medical heat shrink tube
  • performance

    experiment method

    index

    Longitudinal rate of change/%

    ASTM D 2671

    -10~+5

    Tensile strength/MPa

    ASTM D 2671

    >10.4

    Elongation at break/%

    ASTM D 2671

    >200

    Low temperature bending (-30℃, 1h)

    ASM-DTL-23053

    no crack

    Pressure test

    UL 224

    4000V, 1min without breakdown

    Volume resistivity/Ω cm

    IEC 60093

    ≥1015

     

    Specification Table

    model

    Supply inner diameter

    Full shrink size (mm)

    Inner diameter (D)

    wall thickness

    KY-MT-90R-NV-X-4.8-*

    5.20±0.30

    <1.20

    0.51±0.08

    KY-MT-90R-NV-X-6.4-*

    7.00±0.30

    <1.60

    0.51±0.08

    KY-MT-90R-NV-X-9.5-*

    10.00±0.30

    <2.40

    0.51±0.08

    KY-MT-90R-NV-X-12.7-*

    13.50±0.40

    <3.20

    0.64±0.08